Use of remote control in the intraoperative telemetry of cochlear implant: multicentric study

ThumbnailView/Open
Date
2019-07
Author
Tanamati, Liege Franzini
Author
Goffi-Gomez, Maria Valéria Schmidt
Author
Muniz, Lilian Ferreira
Author
|Samuel, Paola Angélica
Author
Wiemes, Gislaine Richter Minhoto
Author
Lima, Daniele Penna
Author
Sílvia Badur Curi
Author
Onuki, Lucia Cristina
Author
Queiroz, Carla Fortunato
Author
Capistrano, Ana Karla Bigois
Author
Moret, Adriane Lima Mortari
Author
Kimura, Márcia Yuri Tsumura
Author
Oyanguren, Valeria
Author
Mauch, Herbert
xmlui.dri2xhtml.METS-1.0.item-type
Artigo
Metadata
Show full item record
Abstract
INTRODUCTION: The conventional evaluation of neural telemetry and impedance requires the use of the computer coupled to an interface, with software that provides visualization of the stimulus and response. Recently, a remote control (CR220®) was launched in the market, that allows the performance of intraoperative tests with minimal instrumentation. OBJECTIVE: To evaluate the agreement of the impedance values and neural telemetry thresholds, and the time of performance in the conventional procedure and by the remote control. METHODS: Multicentric prospective cross-sectional study. Intraoperative evaluations of cochlear implants compatible with the use of CR220® were included. The tests were carried out in the 22 electrodes to compare the time of performance in the two situations. The agreement of the neural telemetry threshold values obtained from five electrodes was analyzed, and the agreement of impedance was evaluated by the number of electrodes with altered values in each procedure. RESULTS: There were no significant difference between the impedance values. There was a moderate to strong correlation between the electrically-evoked compound action potential thresholds. The mean time to perform the procedures using the CR220 was significantly lower than that with the conventional procedure. CONCLUSION: The use of the CR220 provided successful records for impedance telemetry and automatic neural response telemetry.
xmlui.dri2xhtml.METS-1.0.item-title-alternative
Braz J Otorhinolaryngol. 2019 Jul -Aug;85(4):502-509. doi: 10.1016/j.bjorl.2018.04.003.
xmlui.dri2xhtml.METS-1.0.item-source-uri
https://doi.org/10.1016/j.bjorl.2018.04.003
Subject
Cochlear implant
 
Impedance
 
Evoked potential
 
Telemetry
 
URI
http://digital.bibliotecaorl.org.br/handle/forl/421
Collections
  • Artigo [5]

Contact Us | Send Feedback

Divisão de Biblioteca e Documentação do Departamento
de Otorrinolaringologia da Faculdade de Medicina USP

Rua Artur de Azevedo, 46 CEP: 05404-000 São Paulo/SP - Brasil

Tel: (11) 3062-4097 Email: biblioteca@forl.org.br

Medicina USPFORL
Desenvolvido por Logo DGL Sistemas
 

 


Contact Us | Send Feedback

Divisão de Biblioteca e Documentação do Departamento
de Otorrinolaringologia da Faculdade de Medicina USP

Rua Artur de Azevedo, 46 CEP: 05404-000 São Paulo/SP - Brasil

Tel: (11) 3062-4097 Email: biblioteca@forl.org.br

Medicina USPFORL
Desenvolvido por Logo DGL Sistemas